Menu

2963912 - Phoenix Contact Safety Relays

Safety relays Safety relay to emergency stop and safety door monitoring up to SIL 3 or Cat. 4, PL e according to EN ISO 13849, one or two-channel operation, automatically or manually monitored activation, 8 enabling current paths, nominal input voltage 24 V AC/DC


Part #: 2963912
$578.00Add to Cart
Availability :
Backordered

Phoenix Contact Safety Relays

Input Voltage: 24 V AC/DC
Channel: One or Two Channel Operation
Relay Type: Safety
In Accordance With: EN ISO 13849
Contact Type: 8 Enabling Current Paths
Actuation/Activation: Automatically or Manually Monitored
Panel Components Products: Relays
Relays Products: Safety Relays
Product Type: Safety Relays
Contact type: 8 Enabling Current Paths
  • Connection data
    Conductor cross section AWG/kcmil max: 12
    Conductor cross section AWG/kcmil min.: 24
    Conductor cross section solid max.: 2.5 mm²
    Conductor cross section solid min.: 0.2 mm²
    Conductor cross section stranded max.: 2.5 mm²
    Conductor cross section stranded min.: 0.2 mm²
    Stripping length: 7 mm
  • General data
    Ambient temperature (operation): -20 °C ... 55 °C
    Ambient temperature (storage/transport): -40 °C ... 70 °C
    Category according to EN 13849-1: 4
    Depth: 114.5 mm
    Height: 99 mm
    Mechanical service life: Approx. 10<sup>7</sup> cycles
    Mounting position: Any
    Name: Air and creepage distances between the power circuits
    Pollution degree: 2
    Rated insulation voltage: 250 V
    Rated surge voltage / insulation: 4 kV / Basic insulation, (safe isolation, reinforced insulation and 6 kV between input circuit and enabling current paths (63/64, 73/74, 83/84) and between 63/64, 73/74, 83/84 between each other.)
    Relay type: Electromechanically forcibly guided, dust-proof relay.
    Standards/regulations: DIN EN 50178/VDE 0160
    Stop category: 0
    Surge voltage category: III
    Width: 45 mm
  • Input data
    Concurrence input 1/2: Infinite
    Input voltage range in reference to U<sub>N</sub>: 0.85 ... 1.1
    Max. permissible overall conductor resistance: Approx. 11 ? (Input and start circuits at U<sub>N</sub>)
    Nominal input voltage U<sub>N</sub>: 24 V AC/DC
    Recovery time: 1 s
    Typical input current at U<sub>N</sub>: 210 mA AC
    Typical input current at U<sub>N</sub>: 120 mA DC
    Typical release time: 20 ms
    Typical response time: 60 ms (man. start)
    Typical response time: 250 ms (Auto-start)
    Voltage at input/start and feedback circuit: Approx. 24 V DC
  • Output data
    Contact material: AgSnO<sub>2</sub>, + 0.2 µm Au
    Contact type: 8 enabling current paths
    Contact type: 1 signaling current path
    Inrush current, minimum: 25 mA
    Interrupting rating (ohmic load) max.: 144 W (24 V DC, ? = 0 ms)
    Interrupting rating (ohmic load) max.: 288 W (48 V DC, ? = 0 ms)
    Interrupting rating (ohmic load) max.: 110 W (110 V DC, ? = 0 ms)
    Interrupting rating (ohmic load) max.: 88 W (220 V DC, ? = 0 ms)
    Interrupting rating (ohmic load) max.: 1500 VA (250 V AC, ? = 0 ms)
    Limiting continuous current: 6 A
    Maximum inrush current: 6 A
    Maximum interrupting rating (inductive load): 42 W (24 V DC, ? = 40 ms)
    Maximum interrupting rating (inductive load): 42 W (48 V DC, ? = 40 ms)
    Maximum interrupting rating (inductive load): 42 W (110 V DC, ? = 40 ms)
    Maximum interrupting rating (inductive load): 42 W (220 V DC, ? = 40 ms)
    Maximum switching voltage: 250 V AC/DC
    Minimum switching voltage: 15 V AC/DC
    Output fuse: 6 A fast blow
    Output fuse: C6 (24 V AC/DC) automatic device
    Sq. Total current: 50 A<sup>2</sup> (I<sub>TH</sub><sup>2 </sup>= I<sub>1</sub><sup>2</sup> + I<sub>2</sub><sup>2 </sup>+ ... + I<sub>8</sub><sup>2</sup>)
    Switching capacity min.: 0.4 W
Email this page to a friend
Part Number Tags: N/A

This part number has been discontinued by {Manufacturer}. Use the contact form below to find out the new compatible part.

Updating...