Menu

2941455 - Phoenix Contact Relay Module

Relay Module Relay module, with soldered-in miniature switching relay, contact (AgNi+Au): Small to large loads, 2 PDT, 120 V AC/DC input voltage


Part #: 2941455
$113.14Add to Cart
Availability :
Backordered

Phoenix Contact Relay Module

Input Voltage: 120 V AC/DC
Includes: Soldered-in Miniature Switching Relay
Module Type: Relay Module
Contact Type: AgNi+Au, 2 PDTs
Load Size: Small to Large Loads
Product Type: Relay Module
Contact type: AgNi+Au, 2 PDTs
  • Coil side
    Input voltage range in reference to U<sub>N</sub>: 0.8 ... 1.1
    Nominal input current at U<sub>IN</sub>: 6 mA
    Nominal input voltage U<sub>N</sub>: 120 V AC/DC
    Operating voltage display: Yellow LED
    Protective circuit: Bridge rectifier Bridge rectifier
    Typical release time: 10 ms
    Typical response time: 8 ms
  • Connection data
    Conductor cross section AWG/kcmil max: 12
    Conductor cross section AWG/kcmil min.: 24
    Conductor cross section solid max.: 4 mm²
    Conductor cross section solid min.: 0.2 mm²
    Conductor cross section stranded max.: 2.5 mm²
    Conductor cross section stranded min.: 0.2 mm²
    Connection method: Screw connection
    Screw thread: M3
    Stripping length: 8 mm
  • Contact side
    Contact material: AgNi, hard gold-plated
    Contact type: Single contact, 2-PDT
    Interrupting rating (ohmic load) max.: 1.2 W (at 24 V DC)
    Interrupting rating (ohmic load) max.: 120 W (at 24 V DC)
    Interrupting rating (ohmic load) max.: 95 W (for 48 V DC)
    Interrupting rating (ohmic load) max.: 60 W (for 60 V DC)
    Interrupting rating (ohmic load) max.: 40 W (for 110 V DC)
    Interrupting rating (ohmic load) max.: 55 W (for 220 V DC)
    Interrupting rating (ohmic load) max.: 1250 VA (for 250 V AC)
    Limiting continuous current: 50 mA
    Limiting continuous current: 5 A
    Maximum inrush current: 0.2 A
    Maximum inrush current: 6 A
    Maximum switching voltage: 30 V AC
    Maximum switching voltage: 36 V DC
    Maximum switching voltage: 250 V AC/DC
    Note: the following values are applicable if a gold layer is destroyed
  • General data
    Ambient temperature (operation): -20 °C ... 40 °C
    Ambient temperature (storage/transport): -20 °C ... 70 °C
    Assembly instructions: In rows with zero spacing
    Depth: 62.5 mm
    Height: 75 mm
    Mechanical service life: Approx. 2 x 10<sup>7</sup> cycles
    Mounting position: Any
    Operating mode: 100% operating factor
    Pollution degree: 2
    Rated surge voltage / insulation: 4 kV / Basic isolation, (safe isolation, reinforced insulation and 6 kV between input circuit and output contact current paths.)
    Standards/regulations: IEC 60664
    Standards/regulations: EN 50178
    Standards/regulations: IEC 62103
    Surge voltage category: III
    Test voltage relay contact/relay contact: 1 kV AC (50 Hz, 1 min.)
    Test voltage relay winding/relay contact: 4 kV AC (50 Hz, 1 min.)
    Width: 17.5 mm