Menu

2900692 - Phoenix Contact Motor Starter

Hybrid motor starter 4 in 1 hybrid motor starter for reversing 3~ AC motors up to 550 V AC, with 230 V AC input, 0.6 A output current, emergency stop function, and adjustable overload shutdown.


Part #: 2900692
$196.63Add to Cart
Availability :
Backordered

Phoenix Contact Motor Starter

Input Voltage: 230 VAC
Includes: Adjustable Overload Shutdown
Function: Emergency Stop Function
Type: 4 in 1 Hybrid Motor Starter
Used For: Reversing 3~ AC motors up to 550 VAC
Output Current: 0.6 A
Product Type: Motor Starter
  • Connection data
    Conductor cross section AWG/kcmil max: 14
    Conductor cross section AWG/kcmil min.: 26
    Conductor cross section solid max.: 2.5 mm²
    Conductor cross section solid min.: 0.14 mm²
    Conductor cross section stranded max.: 2.5 mm²
    Conductor cross section stranded min.: 0.14 mm²
    Connection method: Screw connection
  • General data
    Ambient temperature (operation): -25 °C ... 70 °C
    Ambient temperature (storage/transport): -40 °C ... 80 °C
    Assembly instructions: Can be aligned with spacing = 20 mm
    Degree of protection: IP20
    Depth: 114.5 mm
    Height: 99 mm
    Mounting position: Vertical (horizontal DIN rail)
    Name: Standards/regulations
    Name: Power station requirements
    Name: Air and creepage distances between the power circuits
    Operating mode: 100% operating factor
    Rated insulation voltage: 500 V
    Rated surge voltage / insulation: 4 kV/safe isolation
    Standards/regulations: DIN EN 50178
    Standards/regulations: EN 60947
    Standards/regulations: DWR 1300 / ZXX01/DD/7080.8d
    Standards/regulations: DIN EN 50178
    Test voltage input/output: 4 kV<sub>rms</sub>
    Width: 22.5 mm
  • Input data
    Indication: Red LED
    Mains frequency: 40 Hz
    Mains frequency: 100 Hz
    Operating voltage display: Green LED
    Protective circuit: Surge protection
    Rated actuating current I<sub>C</sub>: 7 mA
    Rated actuating voltage range with reference to U<sub>C</sub>: 0.4 ... 1.1
    Rated actuating voltage U<sub>C</sub>: 230 V AC
    Rated control supply current I<sub>S</sub>: 4 mA
    Rated control supply voltage range with reference to U<sub>S</sub>: 0.4 ... 1.1
    Rated control supply voltage U<sub>S</sub>: 230 V AC
    Status display: Yellow LED
    Switching threshold "0" signal, voltage: 44 V AC
    Switching threshold "1" signal voltage: 85 V AC
    Typical response time: < 35 ms
    Typical turn-off time: < 80 ms
  • Output data, load relay
    Continuous load current: 6 A
    Leakage current: 0 mA
    Load current: max. 600 mA (see derating curve)
    Nominal output voltage: 500 V AC
    Nominal output voltage: max. 250 V AC
    Nominal output voltage range: 42 V AC ... 550 V AC
    Note: Confirmation 01: Floating PDT contact
    Output name: AC output
    Output name: Acknowledge output
    Rated operating current at AC-51: 0.6 A
    Rated operating current at AC-53a: 0.6 A
    Residual voltage: < 0.2 V
    Surge current: 100 A (t = 10 ms)
    Type of protection: Surge protection
  • Output data, signaling contact
    Measuring via: Current transformer for line current on L1 and L3