2882802 - Phoenix Contact Surge Protection Device

Type 2 surge protection device Combination of pluggable type 2 arrester and residual current circuit breaker(RCD switch) for 3-phase power supply networks (5-conductor system: L1, L2, L3,N, PE).


Part #: 2882802
$345.00Add to Cart
Availability:
Out of Stock

Phoenix Contact Surge Protection Device

Color: Light Gray
Material: PBT, PA
Connecting Thread: M5
Type: 2, DIN Rail Module
Positions: 4
Protection Level: IP20
Nominal Voltage: 240, 415 VAC
Connection: Screw Connection, Biconnect Terminal Block
Product Type: Surge Protection Device
  • Connection, protective circuit
    Conductor cross section AWG/kcmil max: 4
    Conductor cross section AWG/kcmil max: 2
    Conductor cross section AWG/kcmil min.: 12
    Conductor cross section AWG/kcmil min.: 12
    Conductor cross section solid max.: 16 mm²
    Conductor cross section solid max.: 25 mm²
    Conductor cross section solid min.: 4 mm²
    Conductor cross section solid min.: 4 mm²
    Conductor cross section stranded max.: 16 mm²
    Conductor cross section stranded max.: 25 mm²
    Conductor cross section stranded min.: 4 mm²
    Conductor cross section stranded min.: 4 mm²
    Connection method: Screw connection
    Connection method: Biconnect terminal block
    Connection method: Screw connection
    Connection method: Biconnect terminal block
    Connection name: Protective ground connection
    Connection name: Connection protective circuit
    Connection type IN: Biconnect screw terminal block
    Connection type IN: Biconnect screw terminal block
    Connection type OUT: Biconnect screw terminal block
    Connection type OUT: Biconnect screw terminal block
    Screw thread: M5
    Screw thread: M5
    Stripping length: 16 mm
    Stripping length: 16 mm
    Tightening torque: 4.5 Nm
    Tightening torque: 4.5 Nm
  • Protective circuit
    Dimensioning error current: 30 mA
    Immunity to short-circuiting I<sub>nc</sub>: 10 kA Back-up fuse: 63 A
    Rated making and breaking capacity I<sub>m</sub>: 1.5 kA
    Rated residual making and breaking capacity I<sub>?m</sub>: 2.5 kA
    Surge withstand capability: 6 kV (1.2/50 µs)
    Tripping time for 5xI<sub>?n</sub>: ? 40 ms
    Tripping time for I<sub>?n</sub>: ? 300 ms
  • RCD switch
    Ambient temperature (operation): -25 °C ... 40 °C
    Ambient temperature (storage/transport): -40 °C ... 60 °C
    Color: light gray
    Degree of protection: IP20
    Depth: 76 mm
    Design: DIN rail module, two-section, divisible
    Direction of action: 3L-N & N-PE
    Height: 90 mm
    Housing material: PBT / PA
    IEC power supply system: TT
    IEC power supply system: TN-S
    Inflammability class according to UL 94: V0
    Message: Surge protection fault: Optical
    Mounting type: DIN rail: 35 mm
    Number of positions: 4
    Standards for air and creepage distances: IEC 61643-1
    Standards for air and creepage distances: IEC 60664-1
    Standards/regulations: IEC 61643-1 2005
    Standards/regulations: EN 61643-11 2002
    Standards/regulations: IEC 61008-1 2004
    Standards/regulations: IEC 61008-1/A11 2007
    Standards/regulations: IEC 61008-2-1 2000
    Standards/regulations: IEC 60947-3 2005
    Width: 121 mm
  • Standards
    Arrester rated voltage U<sub>C</sub> (L-N): 350 V AC
    Arrester rated voltage U<sub>C</sub> (N-PE): 264 V AC
    EN type: T2
    Ground conductor current I<sub>PE</sub>: ? 1 µA
    IEC category: II
    IEC category: T2
    Impulse operate voltage at 6 kV (1.2/50)µs (N-PE): ? 1.7 kV
    Max. discharge surge current Imax (8/20) µs maximum (L-N): 90 kA (all channels)
    Max. discharge surge current Imax (8/20) µs maximum (L-N): 30 kA
    Max. discharge surge current Imax (8/20) µs maximum (N-PE): 30 kA
    Nominal discharge surge current I<sub>n</sub> (8/20) µs (L-N): 60 kA (all channels)
    Nominal discharge surge current I<sub>n</sub> (8/20) µs (L-N): 20 kA
    Nominal discharge surge current I<sub>n</sub> (8/20) µs (N-PE): 20 kA
    Nominal frequency f<sub>N</sub>: 50 Hz
    Nominal frequency f<sub>N</sub>: 60 Hz
    Nominal load current I<sub>L</sub>: 40 A
    Nominal voltage U<sub>N</sub>: 240 V AC (230/400 V AC ... 240/415 V AC)
    Nominal voltage U<sub>N</sub>: 415 V AC (L-L)
    Protection level U<sub>P</sub> (L-N): ? 2 kV
    Protection level UP (N-PE): ? 2 kV
    Residual voltage (L-N): ? 1.8 kV (at In)
    Residual voltage (L-N): ? 1.5 kV (at 10 kA)
    Residual voltage (L-N): ? 1.2 kV (at 5 kA)
    Residual voltage (L-N): ? 1 kV (at 3 kA)
    Residual voltage (L-PE): ? 2.5 kV (at In)
    Residual voltage (L-PE): ? 2 kV (at 10 kA)
    Residual voltage (L-PE): ? 1.4 kV (at 5 kA)
    Residual voltage (L-PE): ? 1.1 kV (at 3 kA)
    Residual voltage (N-PE): ? 0.7 kV (at In)
    Residual voltage (N-PE): ? 0.4 kV (at 10 kA)
    Residual voltage (N-PE): ? 0.3 kV (at 5 kA)
    Residual voltage (N-PE): ? 0.2 kV (at 3 kA)
    Response time (L-N): ? 25 ns
    Response time (L-PE): ? 100 ns
    Response time (N-PE): ? 100 ns
    Standby power consumption P<sub>C</sub>: ? 90 mVA
    U<sub>T</sub> (TOV-proof): 415 V AC (5 s)
    U<sub>T</sub> (TOV-proof): 1200 V AC (200 ms / N-PE)
Email this page to a friend