2882598 - Phoenix Contact Surge Protection Device

Surge protection device Surge protection in the IP67 screw-on module for measuring sensors, direct mounting with 3/4 NPT outer thread, cable gland for the signal cable, two-stage protective circuit. HART-compatible.


Part #: 2882598
$1.00Order Details
Availability :
Backordered

Phoenix Contact Surge Protection Device

Device Type: Surge Protection Device
Includes: Cable Gland for the Signal Cable, Two-Stage Protective Circuit
Mounting: 3/4 NPT Outer Thread
Compatible with: HART Compatible
Product Type: Surge Protection Device
  • Connection data
    Conductor cross section AWG/kcmil max: 16
    Conductor cross section AWG/kcmil min.: 26
    Conductor cross section solid max.: 1.5 mm²
    Conductor cross section solid min.: 0.14 mm²
    Conductor cross section stranded max.: 1.5 mm²
    Conductor cross section stranded min.: 0.14 mm²
    Connection method: Screw connection
    Connection method: Screw connection
    Connection name: Input/output
    Connection type IN: Screw terminal blocks
    Connection type OUT: Connection line
    Screw thread: M3
    Stripping length: 6 mm
    Tightening torque: 0.6 Nm
  • General
    Ambient temperature (operation): -40 °C ... 85 °C
    Color: silver
    Degree of protection: IP67
    Depth: 148 mm
    Design: Screw-in module
    Direction of action: Line-Line & Line-Earth Ground
    Height: 34 mm
    Housing material: Zinc die-cast, surface bronzed and nickel-plated
    Mounting type: Direct screw connection
    Number of positions: 3
    Standards for air and creepage distances: IEC 60664-1
    Standards for air and creepage distances: VDE 0110-1
    Total surge current (10/350) µs: 2 kA
    Total surge current (8/20) µs: 20 kA
    Width: 34 mm
  • Protective circuit
    Cut-off frequency fg (3 dB), sym. in 150 Ohm system: Typ. 2 MHz
    Cut-off frequency fg (3 dB), sym. in 50 Ohm system: Typ. 6 MHz
    Ground conductor current I<sub>PE</sub>: ? 2 µA
    IEC category: C1
    IEC category: C2
    IEC category: C3
    IEC category: D1
    Input attenuation aE, sym.: Typ. 0.5 dB (? 1.5 MHz / 50 ?)
    Input attenuation aE, sym.: Typ. 0.2 dB (? 300 kHz / 150 ?)
    Lightning test current (10/350) µs, peak value l<sub>imp</sub>: 1 kA
    Max. discharge surge current Imax (8/20) µs maximum (Core-Core): 10 kA
    Max. discharge surge current Imax (8/20) µs maximum (Core-Earth): 10 kA
    Max. discharge surge current Imax (8/20) µs maximum (Shield-Earth): 10 kA
    Max. required back-up fuse: 500 mA (e.g. T in acc. with IEC 127-2/III)
    Maximum continuous operating voltage U<sub>C</sub>: 40 V DC
    Maximum continuous operating voltage U<sub>C</sub>: 28 V AC
    Maximum continuous voltage UC (wire-wire): 40 V DC
    Maximum continuous voltage UC (wire-wire): 28 V AC
    Message: Surge protection fault: None
    Nominal current I<sub>N</sub>: 450 mA (55°C)
    Nominal discharge surge current I<sub>n</sub> (8/20) µs (Core-Core): 10 kA
    Nominal discharge surge current I<sub>n</sub> (8/20) µs (Core-Earth): 10 kA
    Nominal discharge surge current I<sub>n</sub> (8/20) µs (Shield-Earth): 10 kA (optional)
    Nominal pulse current Ian (10/1000) µs (Core-Core): 23 A
    Nominal pulse current Ian (10/1000) µs (Core-Earth): 100 A
    Nominal pulse current Ian (10/1000) µs (Shield-Earth): 100 A
    Nominal voltage U<sub>N</sub>: 24 V DC
    Operating effective current I<sub>C</sub> at U<sub>C</sub>: ? 10 µA
    Output voltage limitation at 1 kV/µs (Core-Core) spike: ? 55 V
    Output voltage limitation at 1 kV/µs (Core-Core) static: ? 55 V
    Output voltage limitation at 1 kV/µs (Core-Earth) spike: ? 450 V (Direct grounding)
    Output voltage limitation at 1 kV/µs (Core-Earth) static: ? 450 V (Direct grounding)
    Output voltage limitation at 1 kV/µs (Shield-Earth) spike: ? 600 V (optional)
    Protection level U<sub>P</sub> (Core-Core): ? 80 V (C2 -5 kA)
    Protection level U<sub>P</sub> (Core-Earth): ? 450 V (C2 -5 kA, direct grounding)
    Protection level U<sub>P</sub> (Shield-Earth): ? 600 V (C2 -5 kA optional)
    Residual voltage at I<sub>n</sub>, (conductor-conductor): ? 55 V
    Residual voltage with Ian (10/1000)µs (conductor-conductor): ? 65 V
    Resistance in series: 2.2 ?
    Response time tA (Core-Core): ? 1 ns
    Response time tA (Core-Earth): ? 100 ns
    Response time tA (Shield-Earth): ? 100 ns
    Surge carrying capacity in acc. with IEC 61643-21 (Core-Core): C2 (10 kV/5 kA)
    Surge carrying capacity in acc. with IEC 61643-21 (Core-Earth): C2 (10 kV/5 kA)
    Surge carrying capacity in acc. with IEC 61643-21 (Shield-Earth): C2 (10 kV/5 kA)
    Total surge current (8/20) µs: 20 kA