Menu

2859453 - Phoenix Contact Surge Protection Device

Type 2 surge protection device Pluggable type 2 arrester (surge arrester) for 3-phase current supply networks with separate N and PE (5-conductor system: L1, L2, L3, N, PE), with remote indication contact. Overall width: 48 mm.


Part #: 2859453
$474.00Add to Cart
Availability:
Out of Stock

Phoenix Contact Surge Protection Device

Includes: Remote Indication contact
Arrester Type: Surge Arrester
Width: 48.0 MM
Product Type: Surge Protection Device
  • Connection, protective circuit
    Conductor cross section AWG/kcmil max: 4
    Conductor cross section AWG/kcmil min.: 12
    Conductor cross section solid max.: 25 mm²
    Conductor cross section solid min.: 2.5 mm²
    Conductor cross section stranded max.: 16 mm²
    Conductor cross section stranded min.: 2.5 mm²
    Connection method: Screw connection
    Connection method: Biconnect terminal block
    Connection type IN: Biconnect screw terminal block
    Connection type OUT: Biconnect screw terminal block
    Screw thread: M5
    Stripping length: 16 mm
    Tightening torque: 4.5 Nm
  • Protective circuit
    Arrester rated voltage U<sub>C</sub> (L-N): 175 V AC
    Arrester rated voltage U<sub>C</sub> (N-PE): 150 V AC
    EN type: T2
    Ground conductor current I<sub>PE</sub>: ? 1 µA
    IEC category: II
    IEC category: T2
    Impulse operate voltage at 6 kV (1.2/50)µs (N-PE): ? 950 V
    Max. discharge surge current Imax (8/20) µs maximum (L-N): 120 kA (all channels)
    Max. discharge surge current Imax (8/20) µs maximum (N-PE): 40 kA
    Max. required backup fuse with branch wiring: 125 A (gL/gG)
    Max. required backup fuse with V-type through wiring: 40 A (gL/gG)
    Nominal discharge surge current I<sub>n</sub> (8/20) µs (L-N): 60 kA (all channels)
    Nominal discharge surge current I<sub>n</sub> (8/20) µs (N-PE): 20 kA
    Nominal frequency f<sub>N</sub>: 50 Hz
    Nominal frequency f<sub>N</sub>: 60 Hz
    Nominal load current I<sub>L</sub>: 40 A (biconnect, 6 mm<sup>2</sup>)
    Nominal load current I<sub>L</sub>: 63 A (2 x 10 mm<sup>2</sup>)
    Nominal voltage U<sub>N</sub>: 120 V AC
    Protection level U<sub>P</sub> (L-N): ? 850 V
    Protection level UP (N-PE): ? 950 V
    Residual voltage (L-N): ? 600 V (at 5 kA)
    Residual voltage (L-PE): ? 700 V (at 5 kA)
    Residual voltage (N-PE): ? 200 V (at 5 kA)
    Response time (L-N): ? 25 ns
    Response time (L-PE): ? 100 ns
    Response time (N-PE): ? 100 ns
    Short-circuit current self-quenching: 100 A (N-PE)
    Short-circuit resistance I<sub>P</sub> with max. backup fuse (effective): 25 kA
    Standby power consumption P<sub>C</sub>: ? 1.75 mW
    U<sub>T</sub> (TOV-proof): 208 V AC (5 s)
    U<sub>T</sub> (TOV-proof): 1200 V AC (200 ms / N-PE)
    U<sub>T</sub> (TOV-safe): 240 V AC (5 s)
  • Remote indicator contact
    Conductor cross section AWG/kcmil max: 16
    Conductor cross section AWG/kcmil min.: 28
    Conductor cross section solid max.: 1.5 mm²
    Conductor cross section solid min.: 0.14 mm²
    Conductor cross section stranded max.: 1.5 mm²
    Conductor cross section stranded min.: 0.14 mm²
    Connection method: Pluggable screw connection
    Connection name: Remote fault indicator contact
    Max. operating current I<sub>max</sub>: 1 A AC (inductive)
    Max. operating current I<sub>max</sub>: 1 A AC (ohmic)
    Max. operating current I<sub>max</sub>: 30 mA DC (inductive)
    Max. operating current I<sub>max</sub>: 200 mA DC (ohmic)
    Maximum operating voltage U<sub>max.</sub> AC: 250 V AC
    Maximum operating voltage U<sub>max</sub> DC: 125 V DC
    Min. permissible switching capacity: 0.12 VA (12 V, 10 mA)
    Screw thread: M2
    Stripping length: 7 mm
    Switching function: PDT contact
    Tightening torque: 0.25 Nm
  • Standards
    Ambient temperature (operation): -40 °C ... 80 °C
    Color: gray
    Degree of protection: IP20
    Depth: 70 mm
    Design: DIN rail module, two-section, divisible
    Direction of action: 3L-N & N-PE
    Height: 98.5 mm
    Housing material: PBT
    IEC power supply system: TT
    IEC power supply system: TN-S
    Inflammability class according to UL 94: V0
    Message: Surge protection fault: Optical, remote indicator contact
    Mounting type: DIN rail: 35 mm
    Number of positions: 4
    Pollution degree: 2
    Standards for air and creepage distances: DIN VDE 0110-1
    Standards for air and creepage distances: IEC 60664-1
    Standards for air and creepage distances: IEC 61643-11
    Standards for air and creepage distances: UL 1449
    Standards for air and creepage distances: IEEE C62.1
    Standards for air and creepage distances: IEEE C62.45
    Standards for air and creepage distances: IEC 61643-1
    Standards/regulations: IEC 61643-1 2005
    Standards/regulations: DIN EN 61643-11 2002
    Standards/regulations: DIN EN 61643-11/A11 2007
    Standards/regulations: IEEE C62.1 / C62.34 / C62.45
    Standards/regulations: UL 1449
    Surge voltage category: III
    Width: 49.2 mm
Email this page to a friend
Part Number Tags: N/A

This part number has been discontinued by {Manufacturer}. Use the contact form below to find out the new compatible part.