2838199 - Phoenix Contact Surge Protection Device

Type 2 surge protection device Surge voltage arrester consisting of base element with remote indicator contact and ground connectors, for mounting on NS 35/7.5, nominal voltage: 230 V AC, 3 + 1 circuit


Part #: 2838199
$500.00Add to Cart
Availability :
Backordered

Phoenix Contact Surge Protection Device

Includes: Remote Indication contact and ground connectors
Channel: 4-Channel for 3+1 Circuits
Arrester Type: Surge Voltage Arrester
Nominal Voltage: 230 VAC
Product Type: Surge Protection Device
  • Connection, protective circuit
    Conductor cross section AWG/kcmil max: 2
    Conductor cross section AWG/kcmil min.: 20
    Conductor cross section solid max.: 35 mm²
    Conductor cross section solid min.: 0.5 mm²
    Conductor cross section stranded max.: 25 mm²
    Conductor cross section stranded min.: 0.5 mm²
    Connection method: Screw connection
    Connection type IN: Biconnect screw terminal block
    Connection type OUT: Biconnect screw terminal block
    Screw thread: M5
    Stripping length: 14.5 mm
    Tightening torque: 4.5 Nm
  • Protective circuit
    Conductor cross section AWG/kcmil min.: 28
    Conductor cross section solid max.: 1.5 mm²
    Conductor cross section solid min.: 0.14 mm²
    Conductor cross section stranded max.: 1.5 mm²
    Conductor cross section stranded min.: 0.14 mm²
    Connection method: Screw connection
    Connection name: Remote fault indicator contact
    Screw thread: M2
    Stripping length: 7 mm
    Switching function: PDT contact
    Tightening torque: 0.25 Nm
  • Remote indicator contact
    Ambient temperature (operation): -40 °C ... 80 °C
    Color: black
    Degree of protection: IP20
    Depth: 65.5 mm
    Design: DIN rail module, two-section, divisible
    Direction of action: 3L-N & N-PE
    Height: 96.8 mm
    Housing material: PBT / PA
    Inflammability class according to UL 94: V0
    Message: Surge protection fault: Optical, remote indicator contact
    Mounting type: DIN rail: 35 mm
    Number of positions: 4
    Pitch unit: 4 Div.
    Standards for air and creepage distances: DIN EN 60664-1
    Width: 70.8 mm
  • Standards
    Arrester rated voltage U<sub>C</sub>: 275 V AC
    Arrester rated voltage U<sub>C</sub> (L-N): 275 V AC
    Arrester rated voltage U<sub>C</sub> (N-PE): 260 V AC
    EN type: T2
    Follow current quenching capacity If (N-PE): 100 A (260 V)
    Ground conductor current I<sub>PE</sub>: ? 1 µA
    IEC category: II
    IEC category: T2
    Impulse operate voltage at 6 kV (1.2/50)µs (N-PE): ? 1.5 kV
    Lightning test current (10/350) µs, peak value l<sub>imp</sub>: 12 kA (N-PE)
    Max. discharge surge current Imax (8/20) µs: 40 kA
    Max. discharge surge current Imax (8/20) µs maximum (L-N): 40 kA
    Max. discharge surge current Imax (8/20) µs maximum (L-PE): 40 kA
    Max. discharge surge current Imax (8/20) µs maximum (N-PE): 40 kA
    Max. required backup fuse with branch wiring: 125 A (gL)
    Nominal discharge surge current I<sub>n</sub> (8/20) µs (L-N): 20 kA
    Nominal discharge surge current I<sub>n</sub> (8/20) µs (L-PE): 20 kA
    Nominal discharge surge current I<sub>n</sub> (8/20) µs (N-PE): 20 kA
    Nominal frequency f<sub>N</sub>: 50 Hz (60 Hz)
    Nominal voltage U<sub>N</sub>: 230 V AC (400 V AC)
    Nominal voltage U<sub>N</sub>: 230 V AC ... 415 V AC
    Protection level U<sub>P</sub> (L-N): ? 1.35 kV
    Protection level U<sub>P</sub> (L-PE): ? 1.6 kV
    Protection level UP (N-PE): ? 1.5 kV
    Residual voltage (L-N): ? 1.35 kV (at In)
    Residual voltage (L-N): ? 1.2 kV (at 10 kA)
    Residual voltage (L-N): ? 1.1 kV (at 5 kA)
    Residual voltage (L-N): ? 0.95 kV (at 3 kA)
    Residual voltage (L-PE): ? 1.6 kV (at In)
    Residual voltage (L-PE): ? 1.35 kV (at 10 kA)
    Residual voltage (L-PE): ? 1.2 kV (at 5 kA)
    Residual voltage (L-PE): ? 1 kV (at 3 kA)
    Residual voltage (N-PE): ? 0.4 kV (at In)
    Residual voltage (N-PE): ? 0.25 kV (at 10 kA)
    Residual voltage (N-PE): ? 0.15 kV (at 5 kA)
    Residual voltage (N-PE): ? 0.1 kV (at 3 kA)
    Response time (L-N): ? 25 ns
    Response time (L-PE): ? 100 ns
    Response time (N-PE): ? 100 ns
    Short-circuit resistance I<sub>P</sub> with max. backup fuse (effective): 25 kA
    Standby power consumption P<sub>C</sub>: ? 360 mVA
    U<sub>T</sub> (TOV-proof): 335 V AC (5 s / L-N)
    U<sub>T</sub> (TOV-proof): 1200 V AC (200 ms / N-PE)
Email this page to a friend