2818931
-
Phoenix Contact Surge Protection Device
Type 1 surge protection device Type 1 / Class I (lightning current arrester) with arc chopping spark gap and ignition electronics, quenching plates for high mains follow-through current quenching capacity, 1-channel. Protection level: 1.5 kV. Housing width: 35 mm (2 Div.)
Part #: 2818931
Phoenix Contact Surge Protection Device
Device Type:
|
Surge Protection Device |
Includes:
|
Arc Chopping Spark Gap and Ignition Electronics, Quenching Plates |
Channel:
|
1 Channel |
Housing width:
|
35.0 MM |
Arrester Type:
|
Lightning Current Arrester |
Protection Level:
|
1.5 kV |
Product Type:
|
Surge Protection Device |
- Connection, protective circuit
Conductor cross section AWG/kcmil max: 1
Conductor cross section AWG/kcmil min.: 6
Conductor cross section solid max.: 50 mm²
Conductor cross section solid min.: 10 mm²
Conductor cross section stranded max.: 35 mm²
Conductor cross section stranded min.: 16 mm²
Connection method: Screw connection
Connection method: Biconnect terminal block
Connection type IN: Biconnect screw terminal block
Connection type OUT: Biconnect screw terminal block
Screw thread: M6
Stripping length: 19 mm
Tightening torque: 8 Nm
- Environmental conditions
Standards/regulations: E DIN VDE 0675-6/A1
Standards/regulations: UL 1449
Standards/regulations: IEEE C62.1
Standards/regulations: IEEE C62.41
Standards/regulations: IEC 61643-1
Standards/regulations: prEN 61643-1
- Protective circuit
100% lightning impulse sparkover voltage (1.2/50)µs: ? 1.5 kV
Arrester rated voltage U<sub>C</sub>: 440 V AC
Arrester rated voltage U<sub>C</sub> (L-N): 440 V AC
Arrester rated voltage U<sub>C</sub> (L-PEN): 440 V AC
EN type: T1
Follow current quenching capacity If (L-N): 50 kA (At 400 V AC)
Follow current quenching capacity If (L-PE): 50 kA (At 400 V AC)
Ground conductor current I<sub>PE</sub>: ? 3 mA
IEC category: I
IEC category: T1
Lightning test current (10/350) µs, charge: 25 As
Lightning test current (10/350) µs, peak value l<sub>imp</sub>: 50 kA
Lightning test current (10/350) µs, specific energy: 625.00 kJ/?
Max. discharge surge current Imax (8/20) µs: 50 kA
Max. required backup fuse with branch wiring: 250 A (gL)
Nominal discharge surge current I<sub>n</sub> (8/20) µs: 50 kA
Nominal discharge surge current I<sub>n</sub> (8/20) µs (L-N): 50 kA
Nominal discharge surge current I<sub>n</sub> (8/20) µs (L-PEN): 50 kA
Nominal frequency f<sub>N</sub>: 50 Hz
Nominal frequency f<sub>N</sub>: 60 Hz
Nominal voltage U<sub>N</sub>: 400 V AC
Operating effective current I<sub>C</sub> at U<sub>N</sub>: ? 3 mA
Protection level U<sub>p</sub>: ? 1.5 kV
Protection level U<sub>P</sub> (L-N): ? 1.5 kV
Protection level U<sub>P</sub> (L-PEN): ? 1.5 kV
Response time: ? 100 ns
Response time (L-N): ? 100 ns
Response time (L-N): ? 100 ns
Short-circuit current self-quenching: 50 kA (400 V)
Short-circuit resistance I<sub>P</sub> with max. backup fuse (effective): 50 kA (At 400 V AC)
- Standards
Ambient temperature (operation): -40 °C ... 85 °C
Color: black
Degree of protection: IP20
Depth: 80.5 mm
Design: Rail-mountable module, one-piece
Direction of action: 1L-N/PE
Height: 149.8 mm
Housing material: PBT/PA-F
Inflammability class according to UL 94: V0
Message: Surge protection fault: Optical
Mounting type: DIN rail: 35 mm
Number of positions: 1
Permissible humidity (operation): ? 95 %
Pitch unit: 2 Div.
Pollution degree: 2
Spark gap insulation: PA 6.6 GF
Spark gap insulation: POM
Standards for air and creepage distances: DIN VDE 0110-1
Standards for air and creepage distances: IEC 60664-1
Standards for air and creepage distances: DIN VDE 0675-6
Standards for air and creepage distances: IEC 61643-1
Standards for air and creepage distances: NF C61-740
Surge voltage category: III
Width: 35.5 mm