Menu

2818850 - Phoenix Contact Surge Protection Device

Surge protection device Attachment plug with replaceable surge protection for coaxial signal interfaces. Connection: N connector female connector/female connector


Part #: 2818850
$125.00Add to Cart
Availability:
Out of Stock

Phoenix Contact Surge Protection Device

Includes: Replaceable Surge Protection
Connection: N Connector, Female/Female
Plug: Attachment Plug
Product Type: Surge Protection Device
  • Connection data
    Connection method: N connector 50 ?
    Connection type IN: N connector, female
  • General
    Ambient temperature (operation): -40 °C ... 80 °C
    Color: nickel
    Degree of protection: IP55
    Depth: 67 mm
    Design: Attachment plug
    Direction of action: Line-Shield/Earth Ground
    Height: 25 mm
    Housing material: Nickel-plated brass
    Mounting type: Connection-specific intermediate plugging
    Pollution degree: 2
    Standards for air and creepage distances: IEC 60664-1
    Surge voltage category: III
    Total surge current (10/350) µs: 2.5 kA
    Total surge current (8/20) µs: 20 kA
    Width: 25 mm
  • Protective circuit
    Capacity (Core-Earth): Typ. 1.5 pF
    Capacity asymmetrical (shield): Typ. 1.5 pF
    Cut-off frequency fg (3 dB), asym. (shield) in 50 Ohm system: > 3 GHz
    IEC category: C2
    IEC category: C3
    IEC category: D1
    Input attenuation aE, asym.: Typ. 0.1 dB (? 1.2 GHz)
    Input attenuation aE, asym.: Typ. 0.2 dB (? 2.2 GHz)
    Lightning test current (10/350) µs, peak value l<sub>imp</sub>: 2.5 kA
    Max. discharge surge current Imax (8/20) µs maximum (Core-Shield): 20 kA
    Maximum continuous operating voltage U<sub>C</sub>: 280 V DC
    Maximum continuous operating voltage U<sub>C</sub>: 195 V AC
    Maximum continuous voltage U<sub>C</sub> (wire-ground): 280 V DC
    Maximum continuous voltage U<sub>C</sub> (wire-ground): 195 V AC
    Nominal current I<sub>N</sub>: 5 A (25°C)
    Nominal discharge surge current I<sub>n</sub> (8/20) µs (Core-Earth): 20 kA
    Nominal discharge surge current I<sub>n</sub> (8/20) µs (Core-Shield): 20 kA
    Nominal pulse current Ian (10/1000) µs (Core-Shield): 100 A
    Operating effective current I<sub>C</sub> at U<sub>C</sub>: ? 1 µA
    Output voltage limitation at 1 kV/µs (Core-Earth) spike: ? 900 V
    Output voltage limitation at 1 kV/µs (Core-Shield) spike: ? 900 V
    Permissible HF power P<sub>max.</sub> at SWR=xx (50 Ohm system): 700 W (VSWR = 1.1)
    Permissible HF power P<sub>max.</sub> at SWR=xx (50 Ohm system): 200 W (VSWR = ?)
    Protection level U<sub>P</sub> (Core-Earth): ? 1.1 kV (C2 - 10 kV / 5 kA)
    Protection level U<sub>P</sub> (Core-Earth): ? 900 V (C1 - 1 kV/500 A)
    Protection level U<sub>P</sub> (Core-Earth): ? 1 kV (C3 - 25 A)
    Protection level U<sub>P</sub> (Core-Earth): ? 1 kV (C3 - 25 A)
    Protection level U<sub>P</sub> (Core-Earth): ? 1 kV (C3 - 25 A)
    Protection level U<sub>P</sub> (Core-Shield): ? 1.1 kV (C2 - 10 kV / 5 kA)
    Protection level U<sub>P</sub> (Core-Shield): 900 V (C1 - 1 kV/500 A)
    Protection level U<sub>P</sub> (Core-Shield): ? 1 kV (C3 - 25 A)
    Protection level U<sub>P</sub> (Core-Shield): ? 1 kV (C3 - 25 A)
    Protection level U<sub>P</sub> (Core-Shield): ? 1 kV (C3 - 25 A)
    Response time tA (Core-Earth): ? 100 ns
    Response time tA (Core-GND): ? 100 ns
    Standing wave ratio SWR in a 50 ? system: Typ. 1.1 (? 2 GHz)
    Surge carrying capacity in acc. with IEC 61643-21 (Core-Earth): C1 (1 kV / 500 A)
    Surge carrying capacity in acc. with IEC 61643-21 (Core-Earth): C2 (10 kV/5 kA)
    Surge carrying capacity in acc. with IEC 61643-21 (Core-Earth): C3 (100 A)
    Surge carrying capacity in acc. with IEC 61643-21 (Core-Earth): D1 (2.5 kA)
    Total surge current (8/20) µs: 20 kA
    VDE requirement class: C2
    VDE requirement class: C3
    VDE requirement class: D1