Menu

2817411 - Phoenix Contact Surge Protection Device

Type 1 surge protection device Type 1 / Class I / B arrester (lightning current arrester) with encapsulated arc chopping spark gap and ignition electronics, 1-channel. Housing width: 17.5 mm (1 Div.)


Part #: 2817411
$502.54Add to Cart
Availability:
Out of Stock

Phoenix Contact Surge Protection Device

Device Type: Surge Protection Device
Includes: Encapsulated Arc Chopping Spark Gap and Ignition Electronics
Channel: 1 Channel
Housing width: 17.5 MM
Arrester Type: Lightning Current Arrester
Product Type: Surge Protection Device
  • Connection, protective circuit
    Conductor cross section AWG/kcmil max: 2
    Conductor cross section AWG/kcmil min.: 20
    Conductor cross section solid max.: 35 mm²
    Conductor cross section solid min.: 0.5 mm²
    Conductor cross section stranded max.: 25 mm²
    Conductor cross section stranded min.: 0.5 mm²
    Connection method: Screw connection
    Connection method: Biconnect terminal block
    Connection type IN: Biconnect screw terminal block
    Connection type OUT: Biconnect screw terminal block
    Screw thread: M5
    Stripping length: 14.5 mm
    Tightening torque: 4.5 Nm
  • Protective circuit
    100% lightning impulse sparkover voltage (1.2/50)µs: ? 0.9 kV
    Arrester rated voltage U<sub>C</sub>: 260 V AC
    Arrester rated voltage U<sub>C</sub> (L-N): 260 V AC
    Arrester rated voltage U<sub>C</sub> (L-PEN): 260 V AC
    EN type: T1
    Follow current quenching capacity If (L-N): 3 kA
    Follow current quenching capacity If (L-PE): 3 kA
    Ground conductor current I<sub>PE</sub>: ? 0.5 mA
    IEC category: I
    IEC category: T1
    Lightning test current (10/350) µs, charge: 17.5 As
    Lightning test current (10/350) µs, peak value l<sub>imp</sub>: 35 kA
    Lightning test current (10/350) µs, specific energy: 305.00 kJ/?
    Max. required backup fuse with branch wiring: 125 A (gL)
    Nominal discharge surge current I<sub>n</sub> (8/20) µs: 35 kA
    Nominal discharge surge current I<sub>n</sub> (8/20) µs (L-N): 35 kA
    Nominal discharge surge current I<sub>n</sub> (8/20) µs (L-PEN): 35 kA
    Nominal frequency f<sub>N</sub>: 50 Hz
    Nominal frequency f<sub>N</sub>: 60 Hz
    Nominal voltage U<sub>N</sub>: 230 V AC
    Operating effective current I<sub>C</sub> at U<sub>N</sub>: ? 0.5 mA
    Protection level U<sub>p</sub>: ? 0.9 kV
    Protection level U<sub>P</sub> (L-N): ? 0.9 kV
    Protection level U<sub>P</sub> (L-PEN): ? 0.9 kV
    Response time: ? 100 ns
    Response time (L-N): ? 100 ns
    Response time (L-N): ? 100 ns
    Short-circuit current self-quenching: 3 kA (260 V)
    Short-circuit resistance I<sub>P</sub> with max. backup fuse (effective): 25 kA
  • Standards
    Ambient temperature (operation): -40 °C ... 85 °C
    Color: black
    Degree of protection: IP20
    Depth: 65.5 mm
    Design: Rail-mountable module, one-piece
    Direction of action: 1L-N/PE
    Height: 89.8 mm
    Housing material: PA
    Inflammability class according to UL 94: V0
    Message: Surge protection fault: None
    Mounting type: DIN rail: 35 mm
    Permissible humidity (operation): ? 95 %
    Pitch unit: 1 Div.
    Standards/regulations: IEC 61643-1 1998
    Standards/regulations: E DIN VDE 0675-6 1989
    Standards/regulations: E DIN VDE 0675-6/A1 1996
    Standards/regulations: E DIN VDE 0675-6/A2 1996
    Width: 17.7 mm
Email this page to a friend
Part Number Tags: N/A

This part number has been discontinued by {Manufacturer}. Use the contact form below to find out the new compatible part.

Updating...