2803072 - Phoenix Contact Surge Protection Device

Surge protection device Attachment plug with surge protection for V.24 interface. Connection: D-SUB-25 male connector/female connector, installation in lines


Part #: 2803072
$230.00Add to Cart
Availability:
Out of Stock

Phoenix Contact Surge Protection Device

Color: Silver/Black
Material: Zinc Die-Cast
Type: Attachment Plug
Positions: 25
Protection Level: IP20
Nominal Current: <= 1 A
Connection: D-SUB 25
Product Type: Surge Protection Device
  • Connection data
    Connection method: D-SUB-25
    Connection type IN: D-SUB-25 male connector
    Connection type OUT: D-SUB-25 female connector
  • Connection, equipotential bonding
    Connection method: Cable connection/DIN rail
  • Connection, protective circuit
    Standards/regulations: IEC 61643-21
  • General
    Ambient temperature (operation): -40 °C ... 85 °C
    Color: silver/black
    Degree of protection: IP20
    Depth: 63 mm
    Design: Attachment plug for DIN rail mounting
    Direction of action: Line-Line & Line-Signal Ground/Shield & Signal Ground/Shield-Earth Ground
    Height: 110 mm
    Housing material: Zinc die-cast
    Mounting type: Connection-specific attachment plug and DIN rail, 35 mm
    Number of positions: 25
    Standards for air and creepage distances: IEC 60664-1
    Standards for air and creepage distances: VDE 0110-1
    Total surge current (8/20) µs: 5 kA
    Width: 25 mm
  • Protective circuit
    Capacity (Core-Core): Typ. 1 nF (f=1 MHz / V<sub>R</sub>= 0 V)
    Capacity (Core-GND): Typ. 2 nF (f=1 MHz / V<sub>R</sub>= 0 V)
    Cut-off frequency fg (3 dB), asym. (GND) in 100 Ohm system: Typ. 1.3 MHz
    Cut-off frequency fg (3 dB), asym. (GND) in 150 Ohm system: Typ. 1.3 MHz
    Cut-off frequency fg (3 dB), sym. in 100 Ohm system: Typ. 2.5 MHz
    Cut-off frequency fg (3 dB), sym. in 150 Ohm system: Typ. 2.5 MHz
    Ground conductor current I<sub>PE</sub>: ? 1 µA
    IEC category: B2
    IEC category: C1
    IEC category: C2
    IEC category: C3
    Input attenuation aE, asym.: Typ. 0.3 dB (? 400 kHz / 100 ?)
    Input attenuation aE, asym.: Typ. 0.3 dB (? 400 kHz / 150 ?)
    Input attenuation aE, sym.: Typ. 0.3 dB (? 700 kHz / 100 ?)
    Input attenuation aE, sym.: Typ. 0.3 dB (? 700 kHz / 150 ?)
    Maximum continuous operating voltage U<sub>C</sub>: 15 V DC
    Maximum continuous operating voltage U<sub>C</sub>: 10 V AC
    Maximum continuous voltage U<sub>C</sub> (wire-GND): 15 V DC
    Maximum continuous voltage U<sub>C</sub> (wire-GND): 10 V AC
    Nominal current I<sub>N</sub>: ? 1 A (25°C)
    Nominal discharge surge current I<sub>n</sub> (8/20) µs (Core-Core): ? 250 A
    Nominal discharge surge current I<sub>n</sub> (8/20) µs (Core-Earth): ? 250 A
    Nominal discharge surge current I<sub>n</sub> (8/20) µs (Core-GND): ? 250 A
    Nominal pulse current Ian (10/1000) µs (Core-Core): 50 A
    Nominal pulse current Ian (10/1000) µs (Core-Earth): 50 A
    Nominal pulse current Ian (10/1000) µs (Core-GND): 50 A
    Nominal pulse current Ian (10/700) µs (Core-Core): 50 A
    Nominal pulse current Ian (10/700) µs (Core-Earth): 50 A
    Nominal pulse current Ian (10/700) µs (Core-GND): 50 A
    Operating effective current I<sub>C</sub> at U<sub>C</sub>: ? 5 µA (per wire)
    Output voltage limitation at 1 kV/µs (Core-Core) static: ? 50 V
    Output voltage limitation at 1 kV/µs (Core-GND) static: ? 30 V
    Protection level U<sub>P</sub> (Core-Core): ? 55 V (B2 - 25 A)
    Protection level U<sub>P</sub> (Core-Core): ? 55 V (C1 - 250 A)
    Protection level U<sub>P</sub> (Core-Earth): ? 400 V (B2 - 25 A)
    Protection level U<sub>P</sub> (Core-Earth): ? 450 V (C1 - 250 A)
    Protection level U<sub>P</sub> (Core-GND): ? 30 V (C1 - 250 A)
    Protection level U<sub>P</sub> (Core-GND): ? 30 V (B2 - 25 A)
    Residual voltage at I<sub>n</sub>, (conductor-conductor): ? 55 V
    Residual voltage at In, (conductor-GND): ? 30 V
    Response time tA (Core-Core): ? 1 ns
    Response time tA (Core-Earth): ? 1 ns
    Response time tA (Core-Earth): ? 100 ns
    Response time tA (Shield-Earth): ? 100 ns
    Surge carrying capacity in acc. with IEC 61643-21 (Core-Core): B2 (1 kV/25 A)
    Surge carrying capacity in acc. with IEC 61643-21 (Core-Core): C1 (500 V / 250 A)
    Surge carrying capacity in acc. with IEC 61643-21 (Core-GND): B2 (1 kV/25 A)
    Surge carrying capacity in acc. with IEC 61643-21 (Core-GND): C1 (500 V/250 A)
    Total surge current (8/20) µs: 5 kA
    VDE requirement class: B2
    VDE requirement class: C1
    VDE requirement class: C2
    VDE requirement class: C3