2800131 - Phoenix Contact Surge Protection Device

Type 1 surge protection device Type 1 / Class I / B arrester (lightning current arrester) with encapsulated arc chopping spark gap, 4-channel for 3 + 1 circuit. Housing width: 70 mm (4 Div.)


Part #: 2800131
$702.08Add to Cart
Availability :
Backordered

Phoenix Contact Surge Protection Device

Device Type: Surge Protection Device
Includes: encapsulated arc chopping spark gap
Channel: 4-Channel for 3+1 Circuits
Housing width: 70.0 MM
Arrester Type: Lightning Current Arrester
Product Type: Surge Protection Device
  • Connection, protective circuit
    Conductor cross section AWG/kcmil max: 2
    Conductor cross section AWG/kcmil min.: 20
    Conductor cross section solid max.: 35 mm²
    Conductor cross section solid min.: 0.5 mm²
    Conductor cross section stranded max.: 25 mm²
    Conductor cross section stranded min.: 0.5 mm²
    Connection method: Screw connection
    Connection method: Biconnect terminal block
    Connection type IN: Biconnect screw terminal block
    Connection type OUT: Biconnect screw terminal block
    Screw thread: M5
    Stripping length: 14.5 mm
    Tightening torque: 4.5 Nm
  • Protective circuit
    Ambient temperature (operation): -40 °C ... 85 °C
    Color: black
    Degree of protection: IP20
    Depth: 65.7 mm
    Design: Rail-mountable module, one-piece
    Direction of action: 3L-N & N-PE
    Height: 95 mm
    Housing material: PA-GF
    IEC power supply system: TT
    IEC power supply system: TN-S
    Inflammability class according to UL 94: V0
    Message: Surge protection fault: None
    Mounting type: DIN rail: 35 mm
    Number of positions: 4
    Permissible humidity (operation): ? 95 %
    Pitch unit: 4 Div.
    Standards for air and creepage distances: EN 60664-1
    Standards for air and creepage distances: EN61643-11
    Width: 70.4 mm
  • Standards
    Arrester rated voltage U<sub>C</sub> (L-N): 350 V AC
    Arrester rated voltage U<sub>C</sub> (N-PE): 260 V AC
    EN type: T1
    Follow current quenching capacity If (L-N): 1.5 kA
    Follow current quenching capacity If (N-PE): 500 A
    Ground conductor current I<sub>PE</sub>: ? 0.1 mA
    IEC category: I
    IEC category: T1
    Impulse operate voltage at 6 kV (1.2/50)µs (L-N): ? 5 kV
    Impulse operate voltage at 6 kV (1.2/50)µs (N-PE): ? 5 kV
    Lightning test current (10/350) µs, charge: 17.5 As
    Lightning test current (10/350) µs, charge: 25 As
    Lightning test current (10/350) µs, peak value l<sub>imp</sub>: 35 kA (L-N)
    Lightning test current (10/350) µs, peak value l<sub>imp</sub>: 50 kA (N-PE)
    Lightning test current (10/350) µs, specific energy: 306.00 kJ/? (L-N)
    Lightning test current (10/350) µs, specific energy: 625.00 kJ/? (N-PE)
    Max. discharge surge current Imax (8/20) µs maximum (L-N): 35 kA
    Max. discharge surge current Imax (8/20) µs maximum (N-PE): 50 kA
    Max. required backup fuse with branch wiring: 400 A (gL)
    Nominal discharge surge current I<sub>n</sub> (8/20) µs (L-N): 35 kA
    Nominal discharge surge current I<sub>n</sub> (8/20) µs (N-PE): 50 kA
    Nominal frequency f<sub>N</sub>: 50 Hz
    Nominal frequency f<sub>N</sub>: 60 Hz
    Nominal voltage U<sub>N</sub>: 230 V AC (400 V AC)
    Protection level U<sub>P</sub> (L-N): ? 5 kV
    Protection level UP (N-PE): ? 5 kV
    Response time: ? 100 ns
    Response time (L-N): ? 100 ns
    Response time (N-PE): ? 100 ns
    Short-circuit resistance I<sub>P</sub> with max. backup fuse (effective): 25 kA
    Standby power consumption P<sub>C</sub>: ? 26 mVA
    U<sub>T</sub> (TOV-proof): 350 V (5 sec /L-N)
    U<sub>T</sub> (TOV-proof): 1200 V AC (200 ms / N-PE)