Menu

2796121 - Phoenix Contact Surge Protection Device

Surge protection device Attachment plug with surge protection for V.11 interface. Connection: D-SUB-15 female/male connector, installation in lines


Part #: 2796121
$285.00Add to Cart
Availability:
Out of Stock

Phoenix Contact Surge Protection Device

Color: Black
Material: Aluminum
Type: Attachment Plug
Protection Level: IP20
Nominal Current: 175 mA
Connection: D-SUB 15
Product Type: Surge Protection Device
  • Connection data
    Connection method: D-SUB-15
    Connection method: V.11
    Connection type IN: D-SUB-15 socket
    Connection type OUT: D-SUB-15 connector
  • Connection, protective circuit
    Standards/regulations: IEC 61643-21
  • General
    Ambient temperature (operation): -40 °C ... 60 °C
    Color: black
    Degree of protection: IP20
    Design: Attachment plug
    Direction of action: Line-Line & Line-Signal Ground/Shield & Signal Ground/Shield-Earth Ground
    Height: 54.5 mm
    Housing material: Aluminum
    Length: 84.6 mm
    Mounting type: Connection-specific intermediate plugging
    Standards for air and creepage distances: VDE 0110-1
    Standards for air and creepage distances: IEC 60664-1
    Total surge current (8/20) µs: 10 kA
    Width: 24.5 mm
  • Protective circuit
    Cut-off frequency fg (3 dB), asym. (PE) in 50 Ohm system: Typ. 5 MHz
    Cut-off frequency fg (3 dB), asym. (PE) in 600 Ohm system: Typ. 500 kHz
    Cut-off frequency fg (3 dB), sym. in 50 Ohm system: Typ. 5 MHz
    Cut-off frequency fg (3 dB), sym. in 600 Ohm system: Typ. 500 kHz
    Ground conductor current I<sub>PE</sub>: ? 4 µA
    IEC category: C1
    IEC category: C2
    IEC category: C3
    IEC category: D1
    Input attenuation aE, asym.: 1.7 dB (? 1 MHz)
    Input attenuation aE, asym.: 0.1 dB (? 600 kHz)
    Input attenuation aE, sym.: 3.2 dB (? 1 MHz)
    Input attenuation aE, sym.: 0.4 dB (? 600 kHz)
    Maximum continuous operating voltage U<sub>C</sub>: 12 V DC
    Maximum continuous voltage U<sub>C</sub> (wire-GND): 12 V DC
    Maximum continuous voltage UC (wire-wire): 12 V DC
    Nominal current I<sub>N</sub>: 175 mA (25°C)
    Nominal discharge surge current I<sub>n</sub> (8/20) µs (Core-Core): 5 kA
    Nominal discharge surge current I<sub>n</sub> (8/20) µs (Core-Earth): 5 kA
    Nominal discharge surge current I<sub>n</sub> (8/20) µs (Core-GND): 5 kA
    Operating effective current I<sub>C</sub> at U<sub>C</sub>: ? 10 µA
    Output voltage limitation at 1 kV/µs (Core-Core) spike: ? 22 V
    Output voltage limitation at 1 kV/µs (Core-Core) static: ? 22 V
    Output voltage limitation at 1 kV/µs (Core-Earth) spike: ? 600 V
    Output voltage limitation at 1 kV/µs (Core-Earth) static: ? 600 V
    Output voltage limitation at 1 kV/µs (Core-GND) static: ? 22 V
    Protection level U<sub>P</sub> (Core-Core): ? 25 V (C2 (4 kV/2 kA))
    Protection level U<sub>P</sub> (Core-Core): ? 30 V (C2 (10 kV/5 kA))
    Protection level U<sub>P</sub> (Core-Earth): ? 700 V (C2 (10 kV/5 kA))
    Protection level U<sub>P</sub> (Core-GND): ? 30 V (C2 (4 kV/2 kA))
    Residual voltage at I<sub>n</sub>, (conductor-conductor): ? 17 V
    Residual voltage at In, (conductor-GND): ? 33 V
    Resistance in series: 22 ?
    Response time tA (Core-Core): ? 1 ns
    Response time tA (Core-Earth): ? 1 ns
    Response time tA (Core-Earth): ? 100 ns
    Surge carrying capacity in acc. with IEC 61643-21 (Core-Core): C2 (10 kV/5 kA)
    Surge carrying capacity in acc. with IEC 61643-21 (Core-Earth): C2 (10 kV/5 kA)
    Surge carrying capacity in acc. with IEC 61643-21 (Core-Earth): D1 (2.5 kA)
    Total surge current (8/20) µs: 10 kA
    VDE requirement class: C1
    VDE requirement class: C2
    VDE requirement class: C3
    VDE requirement class: D1
Email this page to a friend
Part Number Tags: N/A

This part number has been discontinued by {Manufacturer}. Use the contact form below to find out the new compatible part.

Updating...