Phoenix Contact Surge Protection Device

Terminal Type: Modular Terminal Block
Includes: Surge Voltage Fine Protection
Nominal Voltage: 60 VDC
Terminal Width: 6.2 MM
Terminal Height: 47.0 MM
Product Type: Surge Protection Device
  • Connection data
    Conductor cross section AWG/kcmil max: 12
    Conductor cross section AWG/kcmil min.: 24
    Conductor cross section solid max.: 4 mm²
    Conductor cross section solid min.: 0.2 mm²
    Conductor cross section stranded max.: 4 mm²
    Conductor cross section stranded min.: 0.2 mm²
    Connection method: Screw connection
    Connection type IN: Screw terminal blocks
    Connection type OUT: Screw terminal blocks
    Screw thread: M3
    Stripping length: 8 mm
    Tightening torque: 0.5 Nm
  • Connection, protective circuit
    Standards/regulations: IEC 61643-21
  • General
    Ambient temperature (operation): -40 °C ... 85 °C
    Color: black
    Degree of protection: IP20
    Design: Single-level terminal block
    Direction of action: Line-Earth Ground
    Height: 47 mm
    Housing material: PA
    Inflammability class according to UL 94: V2
    Length: 42.5 mm
    Mounting type: DIN rail/G-profile rail
    Number of positions: 1
    Total surge current (8/20) µs: 69 A
    Width: 6.2 mm
  • Protective circuit
    Capacity (Core-Earth): ? 0.65 nF
    Cut-off frequency fg (3 dB), asym. (PE) in 150 Ohm system: Typ. 3.2 MHz
    Ground conductor current I<sub>PE</sub>: ? 5 µA
    IEC category: C3
    Max. discharge surge current Imax (8/20) µs maximum (Core-Earth): 69 A
    Maximum continuous operating voltage U<sub>C</sub>: 70 V DC
    Maximum continuous operating voltage U<sub>C</sub>: 49 V AC
    Maximum continuous voltage U<sub>C</sub> (wire-ground): 70 V DC
    Maximum continuous voltage U<sub>C</sub> (wire-ground): 49 V AC
    Nominal current I<sub>N</sub>: 32 A (50°C)
    Nominal discharge surge current I<sub>n</sub> (8/20) µs (Core-Earth): 69 A
    Nominal pulse current Ian (10/1000) µs (Core-Earth): 13.3 A
    Nominal voltage U<sub>N</sub>: 60 V DC
    Output voltage limitation at 1 kV/µs (Core-Earth) spike: ? 100 V
    Output voltage limitation at 1 kV/µs (Core-Earth) static: ? 100 V
    Residual voltage at I<sub>n</sub>, (conductor-ground): ? 120 V
    Response time tA (Core-Earth): ? 1 ns
    Surge carrying capacity in acc. with IEC 61643-21 (Core-Earth): C3 (10 A)
    Total surge current (8/20) µs: 69 A
    VDE requirement class: C3