Surge protection device Rail-mountable module with surge protection for TTY interface, for mounting on NS 35/7.5, housing width: 30 mm


Part #: 2763523
$179.00Add to Cart
Availability:
Out of Stock

Phoenix Contact Surge Protection Device

Color: Black
Connecting Thread: M3
Type: Rail-Mountable Module
Protection Level: IP20
Nominal Current: 300 mA
Connection: Screw Connection
Product Type: Surge Protection Device
  • Connection data
    Conductor cross section AWG/kcmil max: 12
    Conductor cross section AWG/kcmil min.: 24
    Conductor cross section solid max.: 4 mm²
    Conductor cross section solid min.: 0.2 mm²
    Conductor cross section stranded max.: 2.5 mm²
    Conductor cross section stranded min.: 0.2 mm²
    Connection method: Screw connection
    Connection type IN: Screw terminal blocks
    Connection type OUT: Screw terminal blocks
    Screw thread: M3
    Stripping length: 8 mm
  • Connection, protective circuit
    Standards/regulations: Draft IEC 64644-1
    Standards/regulations: E VDE 0845-3-1
  • General
    Ambient temperature (operation): -20 °C ... 60 °C
    Color: black
    Degree of protection: IP20
    Depth: 54.9 mm
    Design: Rail-mountable module, one-piece
    Direction of action: Line-Line & Line-Earth Ground
    Height: 77.5 mm
    Mounting type: DIN rail: 35 mm
    Width: 27.4 mm
  • Protective circuit
    Cut-off frequency fg (3 dB), sym. in 50 Ohm system: 4 MHz
    Cut-off frequency fg (3 dB), sym. in 600 Ohm system: 300 kHz
    IEC category: C2
    IEC category: C3
    Maximum continuous voltage U<sub>C</sub> (wire-ground): 24 V DC
    Nominal current I<sub>N</sub>: 300 mA
    Nominal discharge surge current I<sub>n</sub> (8/20) µs (Core-Earth): 5 kA
    Operating effective current I<sub>C</sub> at U<sub>C</sub>: ? 10 µA
    Output voltage limitation at 1 kV/µs (Core-Core) spike: ? 35 V
    Output voltage limitation at 1 kV/µs (Core-Core) static: ? 35 V
    Output voltage limitation at 1 kV/µs (Core-Earth) spike: ? 450 V
    Output voltage limitation at 1 kV/µs (Core-Earth) static: ? 450 V
    Protection level U<sub>P</sub> (Core-Core): ? 35 V
    Protection level U<sub>P</sub> (Core-Earth): ? 450 V
    Residual voltage at I<sub>n</sub>, (conductor-conductor): ? 35 V
    Resistance in series: 4.7 ? (Path 10)
    Resistance in series: 4.7 ? (Path 25)
    Response time tA (Core-Core): ? 1 ns
    Response time tA (Core-Earth): ? 100 ns
    VDE requirement class: C2