Menu

2748360 - Phoenix Contact Surge Protection Device

Surge protection device Attachment plug with surge protection for 2-conductor remote bus output. Connection: D-SUB 9 female connector - male connector with ca. 20 cm conductor, snap-on foot for mounting on NS 32 or NS 35/7.5


Part #: 2748360
$222.85Order Details
Availability :
Backordered

Phoenix Contact Surge Protection Device

Color: Black
Material: Aluminum
Type: Attachment Plug
Protection Level: IP10
Nominal Voltage: 5 VDC
Nominal Current: 300 mA
Connection: D-SUB 9
Product Type: Surge Protection Device
  • Connection data
    Connection method: D-SUB-9
    Connection method: Remote bus output
    Connection type IN: D-SUB-9 socket
    Connection type OUT: D-SUB-9 connector
  • Connection, protective circuit
    Standards/regulations: IEC 61643-21
  • General
    Ambient temperature (operation): -40 °C ... 80 °C
    Color: black
    Degree of protection: IP10
    Depth: 70 mm
    Design: Attachment plug for DIN rail mounting
    Direction of action: Line-Line & Line-Earth Ground
    Height: 112.8 mm
    Housing material: Aluminum
    Mounting type: DIN rail: 35 mm
    Standards for air and creepage distances: VDE 0110-1
    Standards for air and creepage distances: IEC 60664-1
    Total surge current (8/20) µs: 1.5 kA
    Width: 16.5 mm
  • Protective circuit
    Capacity (Core-Core): 50 pF
    Capacity (Core-Earth): 50 pF
    Capacity (Core-GND): 50 pF
    Cut-off frequency fg (3 dB), sym. in 150 Ohm system: > 100 MHz
    Cut-off frequency fg (3 dB), sym. in 50 Ohm system: Typ. 100 MHz
    Cut-off frequency fg (3 dB), sym. in 600 Ohm system: Typ. 30 MHz
    Ground conductor current I<sub>PE</sub>: ? 300 µA
    IEC category: C1
    IEC category: C3
    Input attenuation aE, sym.: 0.1 dB (? 7 MHz)
    Input attenuation aE, sym.: 0.1 dB (? 8.5 MHz)
    Input attenuation aE, sym.: 0.1 dB (up to 2.5 MHz 600 Ohm ?)
    Max. discharge surge current Imax (8/20) µs maximum (Core-Earth): 350 A
    Maximum continuous operating voltage U<sub>C</sub>: 5.8 V DC
    Maximum continuous voltage U<sub>C</sub> (wire-ground): 5.8 V DC
    Maximum continuous voltage UC (wire-wire): 5.8 V DC
    Nominal current I<sub>N</sub>: 300 mA (25°C)
    Nominal discharge surge current I<sub>n</sub> (8/20) µs (Core-Core): 350 A
    Nominal discharge surge current I<sub>n</sub> (8/20) µs (Core-Earth): 350 A
    Nominal discharge surge current I<sub>n</sub> (8/20) µs (Core-GND): 350 A
    Nominal voltage U<sub>N</sub>: 5 V DC
    Operating effective current I<sub>C</sub> at U<sub>C</sub>: ? 300 µA
    Output voltage limitation at 1 kV/µs (Core-Core) spike: ? 35 V
    Output voltage limitation at 1 kV/µs (Core-Core) static: ? 12 V
    Output voltage limitation at 1 kV/µs (Core-Earth) spike: ? 35 V
    Output voltage limitation at 1 kV/µs (Core-Earth) static: ? 12 V
    Output voltage limitation at 1 kV/µs (Core-GND) static: ? 12 V
    Protection level U<sub>P</sub> (Core-Core): ? 35 V
    Protection level U<sub>P</sub> (Core-Earth): ? 35 V
    Residual voltage at I<sub>n</sub>, (conductor-conductor): ? 30 V
    Residual voltage at I<sub>n</sub>, (conductor-ground): ? 30 V
    Residual voltage at In, (conductor-GND): ? 30 V
    Response time tA (Core-Core): ? 500 ns
    Response time tA (Core-Earth): ? 500 ns
    Response time tA (Core-Earth): ? 500 ns
    Surge carrying capacity in acc. with IEC 61643-21 (Core-Core): C1 (500 V / 250 A)
    Surge carrying capacity in acc. with IEC 61643-21 (Core-Earth): C1 (500 A/250 A)
    Total surge current (8/20) µs: 1.5 kA
    VDE requirement class: C1
    VDE requirement class: C3
Email this page to a friend
Part Number Tags: N/A

This part number has been discontinued by {Manufacturer}. Use the contact form below to find out the new compatible part.

Updating...