Menu

2692322 - Phoenix Contact Bus Coupler

Bus coupler Inline Modular PROFIBUS bus coupler DP/V1, 8 inputs: 24 V DC, 4 outputs: 24 V DC, 500 mA, 2, 3-conductor connection method


Part #: 2692322
$519.00Add to Cart
Availability :
Backordered

Phoenix Contact Bus Coupler

Input: 8
Output Current: 500 mA
Output: 4
Connection: 2, 3-Conductor Connection Method
Input Voltage: 24 VDC
Output Voltage: 24 VDC
Coupler Type: Inline Modular PROFIBUS bus Coupler DP/V1
Control Technology Products: Profibus Bus Coupler
Product Type: Bus Coupler
  • Digital inputs
    Connection method: Spring-cage connection
    Connection method: 2, 3-wire
    Delay at signal change from 0 to 1: 1.2 ms
    Delay at signal change from 1 to 0: 1.2 ms
    Description of the input: EN 61131-2 type 1
    Input name: Digital inputs
    Input voltage: 24 V DC
    Input voltage range "0" signal: -30 V DC ... 5 V DC
    Input voltage range "1" signal: 15 V DC ... 30 V DC
    Nominal input current at U<sub>IN</sub>: Typ. 3 mA
    Number of inputs: 8
    Protective circuit: Protection against polarity reversal Polarity protection diode
    Typical input current per channel: Typ. 3 mA
    Typical response time: Approx. 500 µs
  • Digital outputs
    Connection method: Spring-cage connection
    Connection method: 2, 3-wire
    Maximum output current per channel: 500 mA
    Maximum output current per module: 2 A
    Maximum output current per module / terminal block: 2 A
    Nominal output voltage: 24 V DC
    Number of outputs: 4
    Output name: Digital outputs
    Output voltage: 24 V DC -1 V (At nominal current)
    Protective circuit: Short-circuit and overload protection Free running circuit
  • General data
    Communications power U<sub>L</sub>: 7.5 V DC ±5%
    Current consumption from U<sub>M</sub>: max. 8 A DC
    Current consumption from U<sub>S</sub>: max. 8 A DC
    I/O supply voltage U<sub>ANA</sub>: 24 V DC
    Main circuit supply U<sub>M</sub>: 24 V DC
    Power supply at U<sub>ANA</sub>: max. 0.5 A DC
    Power supply at U<sub>L</sub>: max. 0.8 A DC
    Power supply at U<sub>M</sub>: max. 8 A DC (Sum of U<sub>M </sub>+ U<sub>S</sub>)
    Power supply at U<sub>S</sub>: max. 8 A DC (Sum of U<sub>M </sub>+ U<sub>S</sub>)
    Segment supply voltage U<sub>S</sub>: 24 V DC
    Supply voltage range U<sub>ANA</sub>: 19.2 V DC ... 30 V DC (including all tolerances, including ripple)
    Supply voltage range U<sub>M</sub>: 19.2 V DC ... 30 V DC (including all tolerances, including ripple)
    Supply voltage range U<sub>S</sub>: 19.2 V DC ... 30 V DC (including all tolerances, including ripple)
  • Inline potential routing
    Connection method: D-SUB-9 female connector
    Connection method: Inline data jumper
    Fieldbus system: PROFIBUS DP
    Fieldbus system: Lokalbus
    Name: PROFIBUS DP
    Name: Inline local bus
    Number of positions: 9
    Transmission speed: 9,6 kBit/s ... 12 MBit/s
    Transmission speed: 500 kbaud/2 Mbaud, can be selected
    Transmission speed: 500 kBit/s / 2 MBit/s (Automatic detection, no combined system)
  • Interface
    Communications power U<sub>L</sub>: 7.5 V DC
    Connection method: Spring-cage connection
    Current consumption: max. 0.98 A (from U<sub>BK</sub>)
    Current consumption: 0.8 A
    Name: Bus coupler supply U<sub>BC</sub>; Communications power U<sub>L</sub> (7.5 V) and the analog supply U<sub>ANA</sub> (24 V) are generated from the bus coupler supply.
    Power consumption: Typ. 1.7 W
    Supply voltage: 24 V DC (via Inline connector)
    Supply voltage range: 19.2 V DC ... 30 V DC (including all tolerances, including ripple)
  • Power supply for module electronics
    Air pressure (operation): 70 kPa ... 106 kPa (up to 3000 m above sea level)
    Air pressure (storage/transport): 70 kPa ... 106 kPa (up to 3000 m above sea level)
    Ambient temperature (operation): -25 °C ... 55 °C
    Ambient temperature (storage/transport): -45 °C ... 85 °C
    Conformance with EMC directives: Noise immunity test in accordance with EN 61000-6-2 Electrostatic discharge (ESD) EN 61000?4?2/IEC 61000?4?2 Criterion B; 6 kV contact discharge, 8 kV air discharge
    Conformance with EMC directives: Noise immunity test in accordance with EN 61000-6-2 Electromagnetic fields EN 61000?4?3/IEC 61000?4?3 Criterion A; Field intensity: 10 V/m
    Conformance with EMC directives: Noise immunity test in accordance with EN 61000-6-2 Fast transients (burst) EN 61000?4?4/IEC 61000?4?4 Criterion A; all interfaces 1 kVCriterion B; all interfaces 2 kV
    Conformance with EMC directives: Noise immunity test in accordance with EN 61000-6-2 Transient surge voltage (surge) EN 61000?4?5/IEC 61000?4?5 Criterion B; supply lines DC: 0.5 kV/0.5 kV (symmetrical/asymmetrical); fieldbus cable shield 1 kV
    Conformance with EMC directives: Noise immunity test in accordance with EN 61000-6-2 Conducted interference EN 61000?4?6/IEC 61000?4?6 Criterion A; Test voltage 10 V
    Conformance with EMC directives: Noise emission test as per EN 61000-6-4 EN 55011 Class A
    Degree of protection: IP20
    Depth: 71.5 mm
    Diagnostics messages: Short-circuit / overload of the digital outputs Yes
    Diagnostics messages: Sensor supply failure Yes
    Height: 119.8 mm
    Mechanical tests: Vibration resistance in acc. with IEC 60068-2-6 5g
    Mechanical tests: Shock test in acc. with IEC 60068-2-27 Operation: 25 g, 11 ms duration, semi-sinusoidal shock impulse
    Mounting type: DIN rail
    Note on dimensions: Specfications with male connectors
    Note on weight specifications: with male connectors
    Permissible humidity (operation): 10 % ... 95 % (according to DIN EN 61131-2)
    Permissible humidity (storage/transport): 10 % ... 95 % (according to DIN EN 61131-2)
    Protection class: III, IEC 61140, EN 61140, VDE 0140-1
    Weight: 320 g
    Width: 80 mm
  • System limits of the bus coupler
    Amount of process data: max. 488 Byte (per station)
    Amount of process data: max. 244 Byte (Input)
    Amount of process data: max. 244 Byte (Output)
    Number of configuration data: max. 244 Byte (including 5 bytes for the local inputs and outputs)
    Number of devices with parameter channel (PCP): max. 16
    Number of local bus devices that can be connected: max. 61 (On board I/Os are two devices)
    Number of parameter data: max. 244 Byte (including 14 bytes for the bus coupler, DP/V1, and the local inputs and outputs)
    Number of supported devices: max. 63 (per station)
    Response time of I/Os: Typ. 4 ms (aligned I/Os; transmission speed: PROFIBUS 1.5 Mbps, local bus 500 kbps)
Email this page to a friend
Part Number Tags: N/A

This part number has been discontinued by {Manufacturer}. Use the contact form below to find out the new compatible part.

Updating...