2320160 - Phoenix Contact Diode Module

Diode module DIN rail diode module 48 V DC/2x20 A or 1x40 A. Uniform redundancy up to the consumer.


Part #: 2320160
$170.95Add to Cart
Availability :
Backordered

Phoenix Contact Diode Module

Input Voltage: 48 VDC
Input Current: 2 x 20 A
Output Current: 1 x 40 A
Product Type: Diode Module
  • Connection data, input
    Conductor cross section AWG/kcmil max: 10
    Conductor cross section AWG/kcmil min.: 12
    Conductor cross section solid max.: 6 mm²
    Conductor cross section solid min.: 0.2 mm²
    Conductor cross section stranded max.: 4 mm²
    Conductor cross section stranded min.: 0.2 mm²
    Connection method: Screw connection
    Screw thread: M3
    Stripping length: 7 mm
  • Connection data, output
    Connection method: Screw connection
  • General data
    Ambient temperature (operation): -40 °C ... 70 °C
    Ambient temperature (storage/transport): -40 °C ... 85 °C
    Assembly instructions: Can be aligned: 5 mm horizontally, 15 mm next to active components, 5 cm vertically
    ATEX: Ex II 3G Ex nA IIC T4 Gc
    ATEX: KEMA 10 ATEX 0165X
    Degree of protection: IP20
    Depth: 125 mm
    Efficiency: > 97 %
    Efficiency: > 97 %
    Electromagnetic compatibility: Conformance with EMC Directive 2004/108/EC
    Height: 130 mm
    IECEx: Ex nA IIC T4 Gc
    IECEx: IECEx KEM 10.0091
    Low Voltage Directive: Conformance with Low Voltage Directive 2006/95/EC
    Max. permissible relative humidity (operation): ? 95 % (at 25 °C, no condensation)
    Mounting position: horizontal DIN rail NS 35, EN 60715
    Net weight: 0.75 kg
    Protection class: III
    Standard - Electrical safety: EN 60950-1/VDE 0805 (SELV)
    Standard - Safe isolation: DIN VDE 0100-410
    Standard - Safe isolation: DIN VDE 0106-1010
    Standard ? Electronic equipment for use in electrical power installations and their assembly into electrical power installations: EN 50178/VDE 0160 (PELV)
    Standard ? Protection against electric shock: DIN 57100-410
    Standard ? Protection against shock currents, basic requirements for protective separation in electrical equipment: DIN VDE 0106-101
    Standard ? Safety extra-low voltage: IEC 60950-1 (SELV) and EN 60204 (PELV)
    UL approvals: UL/C-UL listed UL 508
    UL approvals: UL/C-UL Recognized UL 60950
    UL approvals: UL/C-UL listed ANSI/ISA 12.12.01
    Width: 50 mm
  • Input data
    DC input voltage range: 30 V DC ... 56 V DC
    Maximum current I<sub>max</sub>: 2x 30 A (-25°C ... 40°C)
    Maximum current I<sub>max</sub>: 1x 60 A (-25°C ... 40°C)
    Maximum current I<sub>max</sub>: 2x 30 A (-25°C ... 40°C)
    Maximum current I<sub>max</sub>: 1x 60 A (-25°C ... 40°C)
    Nominal input current I<sub>N</sub>: 2x 20 A (-25 °C ... 60 °C)
    Nominal input current I<sub>N</sub>: 1x 40 A (-25 °C ... 60 °C)
    Nominal input current I<sub>N</sub>: 2x 20 A (-25 °C ... 60 °C)
    Nominal input current I<sub>N</sub>: 1x 40 A (-25 °C ... 60 °C)
    Nominal input voltage: 48 V DC
  • Output data
    Derating: 60 °C ... 70 °C (2.5%/K)
    Output current: 40 A (Increasing power)
    Output current: 20 A (Redundancy)
    Power loss nominal load max.: 14 W (I<sub>OUT</sub> = 20 A)
Email this page to a friend
Part Number Tags: N/A

This part number has been discontinued by {Manufacturer}. Use the contact form below to find out the new compatible part.

Updating...